• Medientyp: E-Artikel
  • Titel: Early detection of multiple myeloma in primary care using blood tests: a case–control study in primary care
  • Beteiligte: Koshiaris, Constantinos; Van den Bruel, Ann; Oke, Jason L; Nicholson, Brian D; Shephard, Elizabeth; Braddick, Mick; Hamilton, William
  • Erschienen: Royal College of General Practitioners, 2018
  • Erschienen in: British Journal of General Practice
  • Sprache: Englisch
  • DOI: 10.3399/bjgp18x698357
  • ISSN: 0960-1643; 1478-5242
  • Schlagwörter: Family Practice
  • Entstehung:
  • Anmerkungen:
  • Beschreibung: <jats:sec><jats:title>Background</jats:title><jats:p>Multiple myeloma is a haematological cancer characterised by numerous non-specific symptoms leading to diagnostic delay in a large proportion of patients.</jats:p></jats:sec><jats:sec><jats:title>Aim</jats:title><jats:p>To identify which blood tests are useful in suggesting or excluding a diagnosis of myeloma.</jats:p></jats:sec><jats:sec><jats:title>Design and setting</jats:title><jats:p>A matched case–control study set in UK primary care using routinely collected data from the Clinical Practice Research Datalink.</jats:p></jats:sec><jats:sec><jats:title>Method</jats:title><jats:p>Symptom prevalence and blood tests were analysed up to 5 years before diagnosis in 2703 cases and 12 157 matched controls. Likelihood ratios (LR) were used to classify tests or their combinations as useful rule-in tests (LR+ = ≥5), or rule-out tests (LR− = ≤0.2).</jats:p></jats:sec><jats:sec><jats:title>Results</jats:title><jats:p>Raised plasma viscosity (PV) had an LR+ = 2.0, 95% confidence interval [CI] = 1.7 to 2.3; erythrocyte sedimentation rate (ESR) 1.9, 95% CI = 1.7 to 2.0; and C-reactive protein (CRP) 1.2, 95% CI = 1.1 to 1.4. A normal haemoglobin had an LR− = 0.42, 95% CI = 0.39 to 0.45; calcium LR− = 0.81, 95% CI = 0.78 to 0.83; and creatinine LR− = 0.80, 95% CI = 0.77 to 0.83. The test combination with the lowest LR− was all normal haemoglobin with calcium and PV, which had an LR− = 0.06, 95% CI = 0.02 to 0.18, though the LR− for normal haemoglobin and PV together was 0.12 (95% CI = 0.07 to 0.23).</jats:p></jats:sec><jats:sec><jats:title>Conclusion</jats:title><jats:p>Plasma viscosity and ESR are better for both ruling in and ruling out the disease compared with C-reactive protein. A combination of a normal ESR or PV and normal haemoglobin is a simple rule-out approach for patients currently being tested in primary care.</jats:p></jats:sec>
  • Zugangsstatus: Freier Zugang